Logic Fire� |
|
|
Applied Control Electronics Inc. Current Products and Development:
Pellet Stove Control Boards:
SPV04 Series: A/C Random Phase / Relay Timer & Controller / Sensor
115/230* 50/60 Hz VAC INPUT / CLASS-2 REGULATED SUPPLY
OTP FACTORY PROGRAMMABLE
FUSED A/C OUTPUT 5A
INPUTS: LOGIC LEVEL for SENSOR/TRIGGER (2)
OUTPUTS/C & DRY SWITCHED
POT ADJUST RANDOM THYRISTOR or N/O RELAY OUTPUT
DRY SWITCH RELAY OUTPUT N/O 5-AMP MAX.
ON/OFF TIMING FOR LOADS (.01 Sec to Hours)
NOM51 Series: Solid State Zero & Relay Adjustable Timer
NOM7000 Series: Solid State & Relay Output Motor / Heater Temperature Load Control
- 115/230* 50/60 Hz VAC INPUT / CLASS-2 REGULATED SUPPLY
MPU / FLASH WITH EPROM (MULTI-PROGRAM MODES)
FUSED A/C INPUT 5A
INPUTS: LOGIC LEVEL USER MODE KEYS (auto & manual modes)
ANALOG RTD TEMP MEASUREMENT
7-SEGMENT DISPLAY for AUTO/MANUAL TEMP & ALARM
OUTPUTS: A/C ZERO THYRISTOR SOLID STATE (2)
OUTPUT: A/C RELAY N/O (1)
ON/OFF TIMING ADJUSTMENT FROM (.01 Sec to Hours)
STANDARD ALARMS: LOW & HIGH TEMP FAULTS
AUTOMATIC SHUTDOWN /FAIL
TRC730 Series: Solid State & Relay for Inductive Motor & Resistive Load control
- 115/230* 50/60 Hz VAC INPUT / CLASS-2 REGULATED SUPPLY
- MPU/ FLASH WITH EPROM (MULTI-PROGRAM MODES)
- FUSED A/C INPUT 5A
- INPUTS: LOGIC LEVEL USER MODE KEYS (manual or remote thermostat)
- 7-SEGMENT & LED STATUS OF OPERATION
- OUTPUT: A/C ZERO OR RANDOM PHASE SOLID STATE (3)
- OUTPUT: A/C RELAY N/O (1)
- ON/OFF MULTI-LEVEL TIMING ADJUST WITH TRIM (.01 Sec to Hours)
- STANDARD ALARMS: LOW TEMPERATURE & AIR PRESSURE FAULTS
- AUTOMATIC SHUTDOWN / FAIL ALARM
230* Denotes factory order program
DHC3110 series: STD-Function Solid State Relay & Motor Control.
DHC4110 series: Flash Programmable Solid State Relay & Motor Control
- 115/230 50/60 Hz VAC INPUT / CLASS-2 REGULATED SUPPLY
- AVR 8-16K FLASH WITH EPROM AND NON-VOLATILE MEMORY
- REMOTE ENGINEERING PROGRAMMING CAPABILITIES
- FUSED A/C INPUT 5A
- INTERNAL & DISPLAY DIAGNOSTICS
- INPUTS: LOGIC LEVEL USER MODE KEYS & DRY SWITCH SENSE
- LED STATUS OF LEVEL CONTROL & ALARM FAULT
- OUTPUT: A/C RANDOM THYRISTOR SOLID STATE (2)
- OUTPUT: A/C ZERO THYRISTOR SOLID STATE (2)
- OUTPUT: A/C RELAY N/O (1)
- ON/OFF MULTI SWITCH TIMING (.01 Sec to Hours)
- STD SENSOR INPUTS: LOW TEMP, HIGH TEMP & AIR PRESSURE FAULTS
- AUTOMATIC SHUTDOWN / ALARM FAIL
- MULTIPLE GRAPHIC KEYPAD OPTIONS
- FOOTPRINT & WIRING COMPATIBLE WITH 3000 SERIES CONTROL
DHC5501 series: Flash programmable Solid State Relay & Motor Control
- 115/230* 50/60 Hz VAC INPUT / CLASS-2 REGULATED SUPPLY
- AVR 16K FLASH WITH EPROM & NON-VOLATILE MEMORY
- REMOTE ENGINEERING PROGRAMMING CAPABILITIES
- INTERNAL FAULT DIAGNOSTICS
- MULTIPLE GRAPHIC KEYPAD OPTIONS
- 5-INDPENDENT FUSED A/C OUTPUTS
- MOTHER MAIN MPU & POWER CONTROL MODULE
- DAUGHTER CONTROL KEYPAD INTERFACE (IDC-20)
- MANUAL OR REMOTE (T-STAT) USER FUNCTION SELECTION
- LED STATUS OF LEVEL CONTROL & FAIL ALARM FAULTS
- INPUTS: LOGIC LEVEL USER KEY & DRY SWITCH SENSE
- LED STATUS OF LEVEL CONTROL & ALARM FAULT
- OUTPUT: A/C RANDOM THYRISTOR SOLID STATE FUSED (2)
- OUTPUT: A/C ZERO THYRISTOR SOLID STATE FUSED (2)
- OUTPUT: A/C RELAY N/O FUSED (1)
- ON/OFF MULTI-SWITCH TIMING (.01 Sec to Hours)
Please click here to know more about TRBC202 System.
|
|
|
|